{{ variable.name }}



Deep-frozen work is not the same order as ordinary frozen work. This reefer truck is built for -20 to -25°C at the loading point, the regime used for ice cream and other products that cannot be allowed to soften, with 120 mm polyurethane walls instead of the 100 mm standard and a heated door seal where the specification calls for it. The body still covers a band such as -20 to +12°C, but the refrigeration unit is sized for the coldest set point required, so the coldest point on the route decides wall thickness, unit capacity and floor design.
| Item | Specification |
|---|---|
| Deep-frozen set point | -20 to -25°C at the loading point |
| Temperature band per body | One body can cover a band such as -20 to +12°C |
| Wall thickness | 120 mm for deep-frozen work; 80-120 mm range, 100 mm standard |
| Panel construction | FRP 1.5-2.0 mm both faces, polyurethane core 38-45 kg/m3, foamed under about 120 kPa |
| Floor | 100-150 mm insulated with aluminium T-section rails |
| Door seal | Multi-lip EPDM gasket, heated seal for deep-frozen work |
| Defrost | Automatic hot-gas or electric defrost |
| Refrigerant | R404A standard, low-GWP option on request |
| Temperature hold | Within plus or minus 1°C |
| Pull-down | Empty body from 30°C ambient to 0°C in 30-60 minutes |
| Body volume / pallets | 10-45 m3, 4-14 pallets (1,200 x 800 mm and 1,200 x 1,000 mm) |
| Body internal size | Length 3,800-9,600 mm, width 2,000-2,450 mm, height 1,800-2,500 mm |
| Monitoring | Digital set point, high and low temperature alarms, data logger with one to four sensors optional |
| Warranty | 12 months major components; unit under unit supplier terms |
Skins are FRP/GRP 1.5-2.0 mm with a food-grade gel coat inside; the core is rigid polyurethane of 38-45 kg/m3. Rear door frames, posts, hinges, locks and handles are stainless steel, interior lining is food-grade FRP or stainless steel 304 with coved corners, and the partition wall, where fitted, is an insulated FRP panel in a stainless frame sealed at floor, walls and roof. Piping is copper with elastomeric insulation, and evaporator and condenser housings are aluminium or ABS.
The set point is turned into a set point and a hold time before the body and unit are sized, so a colder regime is quoted as a different build rather than an option on a standard truck. Left-hand or right-hand drive, Euro II to Euro V engines, tropical cooling, cold-start packages and a low-GWP refrigerant are confirmed at order.
A batch of refrigerated trucks shipped to a food and pharmaceutical distributor in Ghana in February 2025 went through full ex-works inspection before dispatch, so the units were ready to run on arrival and client downtime was reduced. The distributor operates temperature-sensitive cargo across different climates and reported stable temperature control and strong climate adaptability.
Confirm the coldest set point on the route, the hold time required, the daily number of door openings and the ambient at loading. Sales engineers then fix wall thickness, unit capacity, floor design and interior layout before quoting.
Tel: +86-13083602803 · WhatsApp: +86-16638078903 · Email: info@elorry-ind.com · Zhengzhou City, Henan Province, China
reefer-truck-deep-freezer-120mm-body.png — Deep freezer reefer truck with thick insulated body panels.
reefer-truck-deep-freezer-rear-doors.png — Insulated rear doors with multi-lip gasket on a deep frozen reefer body.
reefer-truck-deep-freezer-loading-dock.png — Deep freezer reefer truck parked for loading at a cold store dock.